Home » Products » DC Aquarium pumpBLDC submersible pump (Version 2016)

BLDC submersible pump (Version 2016)

Date:2016/09/01 Views:963

BLDC FREQUENCY PUMP  2016

Product Appearance 



Brightest spot

  • DC pump with wave mode
  • Separate control
  • Silent
  • Low consumption
  • Small body with big flow
  • High pressure
  • Two years Warranty

Features

  • With three modes:Steady flow rate Mode (20 Levels) ,Wave Mode and Feed Mode, the output power could be adjusted to match different size of fish tank.

  • Use SIX-Pole Intelligent DC three-phase driver (without sensor),

  • Low voltage(DC24V) operation ,Safe, Long life expectancy and low noise.

  • With Ceramic shaft & carbon fiber shaft sleeve to make sure the motor’s long expectancy.

  • The input voltage if adapter is widely from AC100 to AC240V/60Hz) which can be suitable for many countries

  • Suitable for both fresh water and Salt water

Technical Data

Model DC40Q-1000L DC40Q-1500L DC40Q-2000L DC52Q-3000L DC52Q-4000L DC52Q-5000L
Flow rate 1000L/H 1500L/H 2000L/H 3000L/H 4000L/H 5000L/H
Head 2.5M 3M 3.5M 3M 4M 5M
Max Consumption 13W 18W 20W 35W 55W 70W
Min Consumption 5W 5W 5W 6W 10W 10W
Voltage DC 24V DC 24V
Dimension 128*123*67 170*167*79
Outlet/Inlet 15mm/20mm 20mm/25mm
Model DC55Q-6000L DC55Q-7000L DC55Q-8000L DC65Q-10000L DC65Q-12000L
Flow rate 6000L/H 7000L/H 8000L/H 10000L/H 12000L/H
Head 4M 4.5M 5M 4M 5M
Max Consumption 55W 70W 85W 85W 100W
Min Consumption 10W 10W 10W 10W 10W
Voltage DC 24V DC 24V
Dimension 170*167*79 206*177*93
Outlet/Inlet 25mm/32mm 25mm/32mm

Instructions (How To Use)

  •  Steady flow Mode(20 levels)
The pump will work in this mode when powered on.you can change the speed by the key of “speed”.when the indicator screen shows the number “101”,that means you have choose the lowest flow rate, when the indicator screen shows the number “120”,that means maximum flow rate.
  • Wave making Mode(20 levels):
Wave was generated by the changing of flow rate(from starting flow to max flow) and need two step of settings:Starting flow and Wave length.
1).Starting Flow:Before working in wave mode, you should adjust the starting flow(Mode 1) into minimum 103 (the starting flow 500L/H), 110 the starting flow 1500L/H.Maximum starting flow 115(3500L/H)
2).Wave length:After the setting of mode 1, press the key of “mode”into mode 2(wave mode),the press speed to change the wave length(20 levels).
  •  Feed mode:
Press the key “Feed” till the indicator screen shows the number “410”. When the number “410” comes out, that means you have chosen Feed Mode successfully. And then the wave maker will stop working for your feeding fishes.Meantime, the indicator screen starts the countdown when it shows the number“410”. The countdown is 10 minutes. When the screen shows the number “400”, that means the count down is over and the wave maker restarts its working

Head-flow curve graph

Dimension